Providing the environmental safety by increasing the efficiency of firefighting in unsheltered timber warehouses

User Rating:  / 1
PoorBest 

Authors:


E.M.Hulida, orcid.org/0000-0002-3881-7206, Lviv State University of Life Safety, Lviv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

I.V.Pasnak, orcid.org/0000-0002-8405-4625, Lviv State University of Life Safety, Lviv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

O.E.Vasylieva, orcid.org/0000-0003-2921-1760, Lviv State University of Life Safety, Lviv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

I.O.Movchan, orcid.org/0000-0001-6287-3948, Lviv State University of Life Safety, Lviv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.


повний текст / full article



Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu. 2021, (1): 123 - 129

https://doi.org/10.33271/nvngu/2021-1/123



Abstract:



Purpose. To develop a method for reducing the impact of fires in unsheltered timber warehouses on the environmental safety by reducing the duration of free burning of timber, the speed of fire front spread, emissions of combustion products and the duration of the firefighting.


Methodology. During the experimental research, the method of fractional factor experiment was used. Theoretical research was performed using optimization mathematical models. The Monte Carlo method is used to solve optimization problems. To implement this method, block diagrams of algorithms was developed, based on written corresponded computer programs.


Findings. The method was developed for reducing the impact of fires in unsheltered timber warehouses on the environmental safety by reducing the duration of free development of the fire, the speed of fire front spread, the concentration of combustion products and the duration of the fire. Fire prevention measures to reduce the duration of fire and to reduce emissions of combustion products due to fires in unsheltered timber warehouses was implemented by using an automated system to determine the fire extinguishing means and forces by setting an optimization problem, applying the Monte Carlo method and developing software to solve it.


Originality. The scientific novelty is the justification of ways to reduce the duration of the free development of fire and to reduce the amount of toxic emissions using optimization mathematical models.


Practical value. It is possible to use the obtained results in the practical activities of fire and rescue units of the SES of Ukraine and provide environmental safety in case of fire in unsheltered timber warehouse due to the practical implementation of administrative, legal and economic methods.



Keywords: unsheltered timber warehouses, fire, duration of free burning, toxic emissions, environmental safety

References.


1. Report on the main results of the Civil Service of Ukraine for Emergencies in 2019 (2020). Kyiv: SES of Ukraine. Retrieved from https://www.kmu.gov.ua/storage/app/sites/1/17-civik-2018/zvit_2019/zvit-2019-dsns.pdf.

2. Campbell, R. (2017). Warehouse fires, 20062015. NFPA Research, Quincy, MA.

3. Koval, A.M. (2015). The speed of propagation of the fire front in open round wood storage of stacked storage. Collection of scientific works Emergencies: prevention and elimination, 1, 66-78. Retrieved from https://www.elibrary.ru/item.asp?id=26295159.

4. Wen-hui, Ju. (2016). Study on Fire Risk and Disaster Reducing Factors of Cotton Logistics Warehouse Based on Event and Fault Tree Analysis. Procedia Engineering,135, 417-425.

https://doi.org/10.1016/j.proeng.2016.01.150.

5. Snityuk, V.E., & Dzhulay, A.N. (2016). An evolutionary method for determining the shortest path of the fire brigade to the fire site with an optimized search space. 12th International Conference Knowledge-Dialogue-Solution. Retrieved from https://artint.com.ua/pdf/Russian/evolfireway_rus.pdf.

6. Vasiliev, M.I., & Koval, O.M. (2014). Reduction of ecological risk due to optimization of fire extinguishing system projects in timber storage. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, (5), 106-113.

7. ulida, E.M., & Renkas, A.A. (2014). Impact of fires on the ecology of the environment. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, (5), 91-100.

8. Voytovych, D.P., & ulida, E.M. (2015). Impact of fire on emissions of toxic combustion products from oil and oil products storage facilities. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, (5), 91-97.

9. Hulida, ., Pasnak, ., Koval, ., & Tryhuba, . (2019). Determination of the Critical Time of Fire in the Building and Ensure Successful Evacuation of People. Periodica Polytechnica Civil Engineering, 63(1), 308-316.

10. SITIS (2012). Recommendations for using the FDS program with PyroSim2012, SmokeView and SITIS: Flammer. Ekaterinburg: Sitis. Retrieved from https://sitis.ru/files/770a17cb8290364068d5fd176f1f30b7.

11. Safety Guide Methods of assessing risk of accidents at hazardous production facilities oil and gas refining, oil and chemical industries (2014). Moscow: Closed Joint Stock Company Scientific and Technical Research Center of Industrial Safety. Retrieved from https://docs.cntd.ru/document/1200136968.

12. DBN B.2.2-12: 2019. Planning and development of territories [Valid from 2019-10-01]. Official publishing house (2019). Kyiv: Ukrarkhbudinform. Retrieved from https://www. minregion.gov.ua/wp-content/uploads/2019/06/B2212-IB.pdf.

13. Hulida, E.M. (2016). Influence of fire risk on fire losses in the rooms of various facilities. Fire safety, 28, 36-42.

14. Koval, O.M. (2013). Speed of fire front spreading in open lumber storage. Fire safety: theory and practice, 13, 123-131.

15. DBN B.2.5-64:2012. Internal water supply and canalization. Part I. Projecting. Part II. onstruction [Valid from 2013-03-01] (2013). Kyiv: Minrehionbud. Retrieved from https://www.minregion.gov.ua/wp-content/uploads/2017/12/99.1.-DBN-V.2.5-642012.-Vnutrishniy-vodoprovid-ta-kanali.pdf.

16. DBN .2.5-56:2014. Fire protection systems [Valid from 2015-07-01]. (2013). Kyiv: Minrehionbud, 132. Retrieved from https://www.minregion.gov.ua/wp-content/uploads/2017/12/98.1.-DBN-V.2.5-562014.-Sistemi-protipozhezhnogo-zahistu.pdf.

17. DSTU 8828: 2019. Fire safety. General provisions [Valid from 2020-01-01] (2020). Kyiv: UkrNDICZ. Retrieved from

https://online.budstandart.com/ua/catalog/doc-page.html?id_doc=82138.

 

Visitors

7564841
Today
This Month
All days
4123
87327
7564841

Guest Book

If you have questions, comments or suggestions, you can write them in our "Guest Book"

Registration data

ISSN (print) 2071-2227,
ISSN (online) 2223-2362.
Journal was registered by Ministry of Justice of Ukraine.
Registration number КВ No.17742-6592PR dated April 27, 2011.

Contacts

D.Yavornytskyi ave.,19, pavilion 3, room 24-а, Dnipro, 49005
Tel.: +38 (056) 746 32 79.
e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
You are here: Home Archive by issue 2021 Content №1 2021 Providing the environmental safety by increasing the efficiency of firefighting in unsheltered timber warehouses