Improvement of method of calculation of efficiency of storm sewage-purification facilities without detention at motor transport enterprises
- Details
- Category: Geotechnical and mining mechanical engineering, machine building
- Last Updated on 05 January 2013
- Published on 05 January 2013
- Hits: 3896
Authors: A.A. Samoylenko, K.M. Bas, V.V. Кrivda, Т.Р. Bas
The article considers the existing method of calculation of efficiency of storm sewage-purification facilities without detention. Some mistakes in regulatory literature were pointed out during calculation of efficiency of storm sewage. The article considers possibilities of improvement of the existing method by taking into account variability of some design parameters. New design formulae and charts ensuring the increase of accuracy and reliability of the existing calculation methods are offered.
Files:
2010_11-12 Sam | |
2012-12-14 517.61 KB 1637 |
Tags: treatment facilities • runoff • partially separate sewerage system • input-output characteristic of pipeline • surface density time • motor transport enterprises