Recirculation power in the balance of hydraulic losses of centrifugal pump

User Rating:  / 0
PoorBest 

Authors:

V. Boiko, orcid.org/0000-0003-1018-0642, National Technical University of Ukraine “Igor Sikorsky Kyiv Politechnic Institute”, Kyiv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

M. Sotnyk, orcid.org/0000-0002-4761-8161, Sumy State University, Sumy, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

V. Moskalenko, orcid.org/0000-0002-8958-3921, Sumy State University, Sumy, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

A. Chernobrova, orcid.org/0000-0002-2319-3189, Sumy State University, Sumy, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

повний текст / full article

 

Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu. 2020, (5): 082-088

https://doi.org/10.33271/nvngu/2020-5/082

Abstract:

Purpose. Improving the methodology for determining the recirculation power of low and medium specific speed centrifugal pumps in order to determine ways to increase their energy efficiency.

Methodology. A numerical simulation based on the physical nature of the phenomena of recirculation power, conducted using the ANSYS CFX software.

Findings. The dynamics of changes in the integral parameters of the operational process of a centrifugal pump D2000-100-2 at flow rates that deviate from optimal (Qopt) are investigated and presented. Based on the results of the numerical simulation, the values of the theoretical head of the impeller, as well as the head at its outlet, taking into account and excluding recirculation, are determined. Due to the difference in the obtained head values, the value of the power losses for recirculation and their part in the balance of hydraulic losses are determined. Based on the simulation results of the operational process of the centrifugal pump D2000-100-2, it is shown that part of the recirculation losses in the flow rate range (0.7–0.4)·Qopt is 25–30 % of the total hydraulic losses, while in the flow rate range (0.3–0.1)·Qopt it increases to 44 %.

Originality. Further development of the method for determining the recirculation power which is based on the results of numerical simulation of three-dimensional fluid flow in the flowing part of the centrifugal pump, taking into account the circulation vortex processes at the outlet of the impeller.

Practical value. Definition of the recirculation power in the power balance of hydraulic losses at the pump design stage. Taking account of the influence of the design parameters of the impeller on the value of recirculation.

References.

1. Lombardo, M. (2015). Ways to improve the efficiency of centrifugal pumps. Theoretical aspects and operating experience. Pumps. Turbines. Systems, 4(17), 34-42.

2. Lomakin, V. O., & Chaburko, P. S. (2015). Influence of flow swirling on the hydraulic efficiency of the pump. Engineering journal, 10, 4-8.

3. Kulikov, A. A., Smolyakov, A. F., Ivanova, I. V., & Dyukova, I. N. (2017). Thermodynamic analysis of dynamic processes in a centrifugal pump. Bulletin of the St. Petersburg Forestry Academy, 221, 197-217. https://doi.org/10.21266/2079-4304.2017.221.197-217.

4. Spiridonov, E. K. (2015). Characteristics and calculation of cavitation mixers. Procedia Engineering, 129, 446-450. https://doi.org/10.1016/j.proeng.2015.12.148.

5. Rotodynamic pumps. Hydraulic performance acceptance tests. Grades 1, 2 and 3. ISO 9906:2012 (E) (2012). Switzerland: International Organization for Standardization.

6. Moskalenko, V., Sotnyk, M., & Boiko, V. (2017). Head pulsations in a centrifugal pump. IOP Materials Science and Engineering, 233, 1-8. https://doi.org/10.1088/1757-899X/233/1/012058.

7. Valyukhov, S. G., & Kretinin, A. V. (2016). Mathematical modeling of hydrodynamic processes in the flow path of a centrifugal pump using neural network algorithms. Pumps. Turbines. Systems, 3(20), 53-59.

8. Liu, H., Ding, J., Dai, H., Tan, M., & Tang, X. (2014). Numerical Research on Hydraulically Generated Vibration and Noise of a Centrifugal Pump Volute with Impeller Outlet Width Variation. Mathematical Problems in Engineering, 2, 1-13.

9. Tsutsumi, K., Watanabe, S., Tsuda, S., & Yamaguchi, T. (2017). Cavitation simulation of automotive torque converter using a homogeneous cavitation model. European Journal of Mechanics – B/Fluids, 61(2), 263-270. https://doi.org/10.1016/j.euromechflu.2016.09.001.

10. Valyukhov, S. G., Kretinin, A. V., Galdin, D. N., & Baranov, S. S. (2015). Optimization design of the flow path of the main oil pump using TURBO ANSYS tools. Pumps. Turbines. Systems, 14(1), 56-68.

11. ANSYS CFX 13.0 Solver Theory. Release 13.0 (2011). Retrieved from http://www.ansys.com.

12. Moskalenko, V. V., Boyko, V. S., & Sotnik, M. I. (2016). Modeling of special operating modes of electromechanical systems of the water supply network. Electrical engineering & Electromechanics, 4(1), 4-9.

13. Baulin, M. N., Nemtinova, D. A., Obolonskaya, E. M., Obolonskaya, O. Y., & Shoter, P. I. (2016). Computational study of fluid flow in a centrifugal pump in Ansys CFX environment. Pumps. Turbines. Systems, 2(19), 75-79.

Visitors

7350472
Today
This Month
All days
1505
39975
7350472

Guest Book

If you have questions, comments or suggestions, you can write them in our "Guest Book"

Registration data

ISSN (print) 2071-2227,
ISSN (online) 2223-2362.
Journal was registered by Ministry of Justice of Ukraine.
Registration number КВ No.17742-6592PR dated April 27, 2011.

Contacts

D.Yavornytskyi ave.,19, pavilion 3, room 24-а, Dnipro, 49005
Tel.: +38 (056) 746 32 79.
e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
You are here: Home Archive by issue 2020 Contens №5 2020 Recirculation power in the balance of hydraulic losses of centrifugal pump