Effect of voltage flicker on leakage current in mine electrical networks containing power electronic devices
- Details
- Category: Content №4 2025
- Last Updated on 26 August 2025
- Published on 30 November -0001
- Hits: 3416
Authors:
Do Nhu Y1, orcid.org/0000-0001-6395-2875, Hanoi University of Mining and Geology, Hanoi, Socialist Republic of Vietnam
Trinh Quyet Thang, orcid.org/0009-0007-5001-4813, Hanoi University of Mining and Geology, Hanoi, Socialist Republic of Vietnam; Hanoi College of Industrial Economics, Hanoi, Socialist Republic of Vietnam
Le Anh Tuan, orcid.org/0009-0001-8695-7457, Hanoi University of Industry, Hanoi, Socialist Republic of Vietnam
Do Anh Tuan, orcid.org/0000-0002-1462-7627, A Chau Industrial Technology Joint Stock Company, Hanoi, Socialist Republic of Vietnam
Ngo Xuan Cuong*, orcid.org/0000-0002-0571-2168 Hue University, School of Engineering and Technology, Thua Thien Hue, Socialist Republic of Vietnam, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
* Corresponding author e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu. 2025, (4): 117 - 125
https://doi.org/10.33271/nvngu/2025-4/117
Abstract:
Purpose. To build a mathematical and simulation model to evaluate the effect of voltage flicker on leakage current in an underground mine AC power network containing power electronic devices.
Methodology. The research methods used in this study include theoretical method to build the equation of leakage current and simulation modeling method on Matlab/Simulink software to determine the leakage current values in each case of voltage flicker.
Findings. In addition to the theoretical analysis on the mine power network model, the paper also evaluates the mine power network model containing the converter on Matlab/Simulink with the model parameters U = 1,140 V, C = 0.19 uF/phase, R = 168 k/phase. The research results show that in the case of low voltage flicker with voltage amplitude lower than 50 % of rated voltage in ½ network cycle, the leakage current before the inverter decreases by the largest 19.7 % and the leakage current after the inverter decreases by the largest 5.2 % compared to the leakage current value at normal voltage. In the case of overvoltage flicker with voltage amplitude higher than 150 % of rated voltage in ½ network cycle, the maximum leakage current before the inverter increases by 33.6 %, the maximum leakage current after the inverter increases by 47.4 % compared to the leakage current value at normal voltage. This problem causes the phenomenon of mistaken operation of the leakage protection relay and causes unsafety in mining.
Originality. The study includes the introduction of a leakage current model in an underground mine’s AC power network containing power electronic devices and the simulation to find out the influence of voltage flicker on the leakage current in that power network using Matlab/Simulink software.
Practical value. The research results indicate the need for measures to minimize voltage flicker, thereby improving the reliability of leakage protection and improving safety in mining.
Keywords: voltage quality, voltage flicker, power electronics, leakage current, mine power network
References.
1. Morán, L., Espinoza, J., & Burgos, R. (2014). Voltage regulation in mine power distribution systems: Problems and solutions. IEEE Industry Application Society Annual Meeting, 1-7. https://doi.org/10.1109/IAS.2014.6978453
2. Sukanth, T., Jayanthu, S., & Jayalaxmi, A. (2016). Mitigation of power quality problem in underground mine using different control strategies. IEEE Region 10 Humanitarian Technology Conference (R10-HTC), 1-4. https://doi.org/10.1109/R10-HTC.2016.7906798
3. IEEE Recommended Practice for Monitoring Electric Power Quality, in IEEE Std 1159-2019 (2019). Revision of IEEE Std 1159-2009, (pp. 1-98).
4. Nguyen, Q. V., & Kim, L. N. (2014). Modeling the power system 1140 voltage of underground mines in Quang Ninh area with the view of safety from electrical shock. Journal of Mining and Earth Sciences, 49-53. Retrieved from https://tapchi.humg.edu.vn/en/archives?article=203
5. Yaghoobi, J., Abdullah, A., Kumar, D., Zare, F., & Soltani, H. (2019). Power quality issues of distorted and weak distribution networks in mining industry: A review. IEEE Access, 7, 162500-162518. https://doi.org/10.1109/ACCESS.2019.2950911
6. Zhongfu, L., Guiying, H., & Lixin, S. (2015). Study on selective leakage protection system of mine low-voltage grid based on internet of things. International Journal of Smart Home, 9(7), 123-134. https://doi.org/10.14257/ijsh.2015.9.7.13
7. Rowe, C. N., Summers, T. J., Betz, R. E., & Gay, D. J. (2013). The correction of voltage sag on mining machines utilising a locally connected STATCOM in the IDEA lab. Australasian Universities Power Engineering Conference (AUPEC), 1-6. https://doi.org/10.1109/AUPEC.2013.6725447
8. Sangepu, R., & Muni, V. (2015). Effect of power quality issues in power system and its mitigation by power electronics devices. The International Daily journal, 2278-5469. Retrieved from https://www.researchgate.net/publication/325676538
9. Do, N. Y., Ngo, X. C., & Nguyen, T. H. (2023). Effect of Power Quality on the Performance of Explosion-Proof Transformers in Mining in Vietnam. Inżynieria Mineralna, 52(2), 65-69. http://doi.org/10.29227/IM-2023-02-13
10. Medeiros, C., & De Oliveira, J. (2002). Effects of voltage fluctuation associated to flicker limits on equipments performance. 10th International Conference on Harmonics and Quality of Power, Proceedings, 1, 347-352. https://doi.org/10.1109/ICHQP.2002.1221458
11. Do Nhu, Y., Thuy, T.B., & Cuong, N.X. (2024). Rotor Configuration for Improved Working Characteristics of Lspmsm in Mining Applications. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, (3), 79-86. https://doi.org/10.33271/nvngu/2024-3/079
12. Liu, Y., Li, D., Yuan, W., Meng, G., & Zhao, Y. (2015). Research on Remote Monitoring System for Leakage Protection of Electric Grid in Underground Mine. First International Conference on Information Sciences, Machinery, Materials and Energy. 704-708. https://doi.org/10.2991/icismme-15.2015.146
13. Wang, X., & Xia, T. (2014). Research on on-line insulation monitoring and fault location method of mine power supply XLPE cable. IEEE Conference and Expo Transportation Electrification Asia-Pacific, 1-4. https://doi.org/10.1109/ITEC-AP.2014.6940919
14. Lia, Z.-K., & Wang, L.-J. (2023). Study on Selective Insulation On-line Monitoring Technology for Mine Power Network. E3S Web of Conferences, 369, 02003. https://doi.org/10.1051/e3sconf/202336902003
15. Siostrzonek, T., Wójcik, J., Dutka, M., & Siostrzonek, W. (2024). Impact of Power Quality on the Efficiency of the Mining Process. Energies, 17(22), 5675. https://doi.org/10.3390/en17225675
16. Geng, J. M., & Li, C. G. (2012). Leakage Failure and Principle of Underground Low Voltage Grid. Applied Mechanics and Materials, 214, 254-258. https://doi.org/10.4028/www.scientific.net/AMM.214.254
17. Ma, H. W., Xing, W., Mao, Q. H., & Liu, Y. (2014). The Protection System Design of Leakage, Undervoltage and Overvoltage for Electromagnetic Starter in Coal Mine. Advanced Materials Research, 1049, 720-725. https://doi.org/10.4028/www.scientific.net/AMR.1049-1050.720
18. Wymann, T., Pollock, M., & Rees, J. (2015). A new approach to mining earth leakage protection with medium voltage drives. Industrial-Electrix, 1-4.
19. Do, N. Y., & Ngo, X. C. (2022). Effects of Voltage Unbalance on Matrix Converter Induction Motor Drive. International Conference on Engineering Research and Applications, 468-476. https://doi.org/10.1007/978-3-031-22200-9_53
20. Jayanthu, S., & Jayalakshmi, A. (2017). Improvement of Power Quality in Underground Coal Mines Using Controllers. Modelling, Measurement and Control C, 78(3), 274-288. https://doi.org/10.18280/mmc_c.780302
21. Ngo, X. C., Do, N. Y., & Tran, Q.H. (2020). The Influence of Voltage Quality on Asynchronous Motor Performance of EKG Excavator in Open Pit Mines-Vinacomin. Inżynieria Mineralna, 1(2), 139-145. https://doi.org/10.29227/IM-2020-02-18
22. Ngo, X. C., & Do, N. Y. (2021). Influence of Harmonics on the Working Efficiency of a 6/1.2 kV Transformer in a Pit Mine. Inżynieria Mineralna, (2), 149-156. https://doi.org/10.29227/IM-2021-02-12
23. Wang, Z. (2008). Analyzing flicker and harmonics in a typical Dutch MV and LV grid, 1-9. Retrieved from https://pure.tue.nl/ws/portalfiles/portal/46919680/638521-2.pdf
24. Do, N. Y., & Ngo, X. C. (2021). Influence of Single-Phase Voltage Loss and Load Carrying Mode on Mine Drainage Pump Motor in Vietnam. Inżynieria Mineralna, 1(2). https://doi.org/10.29227/IM-2021-02-31
25. Nguyen, T. G., Nguyen, T. K., Ngo, X. C., & Do, N. Y. (2023). Research on Electric Leakage Protection to Improve Electrical Safety in Underground Mining in Vietnam. Inżynieria Mineralna, (2), 209-214. https://doi.org/10.29227/IM-2023-02-32
26. Giang, N. T., Do Nhu, Y., Phuc, T. H., Khanh, N. T., & Cuong, N. X. (2023). Improving Electricity Efficiency by DC Power Transmission: A Case Study in Vietnamese Mining. IOP Conference Series: Earth and Environmental Science. 1275(1), 012050. https://doi.org/10.1088/1755-1315/1275/1/012050
27. Giang, N. T., Nhu, D. Y., Khanh, N. T., & Cuong, N. X. (2023). Study of leakage current in underground mine power network: a case study in mining in Vietnam. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, (6), 86-92. https://doi.org/10.33271/nvngu/2023-6/086
28. Nhu, D. Y., Giang, N. T., Tuan, L. A., Cuong, N. X., & Khanh, N. T. (2025). Impact of power electronics devices on leakage current in mine electrical systems: a case study in vietnam. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, (1), 55-62. https://doi.org/10.33271/nvngu/2025-1/055
29. Olszowiec, P. (2017). Voltages and Currents in Output Circuits of Three-Phase Diode Rectifiers. Power and electrical engineering, 34, 25-29. https://doi.org/10.7250/pee.2017.005
30. Olszowiec, P. (2016). Evaluation of Variation Ranges of Phase Voltages and Ground Currents in Three-Phase Unearthed Networks with Diode Rectifiers. Power Electrical Engineering, 33, 51-55. https://doi.org/10.7250/pee.2016.010
31. Olszowiec, P. (2016). Modifications of diode rectifier circuits for continuous insulation measurement in live AC it networks. Electrical engineering & electromechanics, (2), 43-46. https://doi.org/10.20998/2074-272X.2016.2.08
32. Nam, N. V., & Quan, N. M. (2021). Research switching overvoltages in low voltage networks in Viet Nam and proposed limited solutions. Vietnam Journals OnLine, 57(5), 16-21. Retrieved from https://vjol.info.vn/index.php/dhcnhn/article/view/63461
33. C37.011-2019 – IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V, in IEEE Std C37.011-2019 (2019). Revision of IEEE Std C37.011-2011, (pp. 1-127).
34. C4/B5.41, C. (2017). Transient Recovery Voltage (TRV) and Rate of Rise of Recovery. Voltage (RRRV) of Line Circuit Breakers in Over Compensated Transmission Lines.
Newer news items:
- The impact of the institutional environment on the investment attractiveness of the national economy: international experience - 26/08/2025 01:18
- Building a technological ecosystem in the context of digital transformation - 26/08/2025 01:18
- Algorithm for scheduling drivers on intercity road routes: case study of the shift method - 26/08/2025 01:18
- Paradigms of modeling and improving the reliability of data transmission in VLC technologies - 26/08/2025 01:18
- The array of GNSS for structure deformation monitoring - 26/08/2025 01:18
- Development of a clustering algorithm for parameters of explosive objects based on a comprehensive indicator - 26/08/2025 01:18
- Software detection of Ukrainian-language texts generated by AI: methods, estimations, challenges - 26/08/2025 01:18
- Integration of nuclear and hydrogen technologies to improve the efficiency of power generation and storage - 26/08/2025 01:18
- The impact of addition of different shapes of tire waste on soil properties - 26/08/2025 01:18
- Probabilistic soil-rock degradation due to heavy metal existence in Tashan-Kaji, Toro LGA (Nigeria) - 26/08/2025 01:18
Older news items:
- Mathematical simulation of brushless high-speed permanent magnet motor - 26/08/2025 01:18
- Instantaneous power of a doubly fed induction generator with the unbalanced stator windings - 26/08/2025 01:18
- Analysis of a soil slope stability based on modified failure criterion - 26/08/2025 01:18
- Determination of bronze БрА7К2О1,5Мц0,3 crystallization interval limit values and phase transformations - 26/08/2025 01:18
- Methodology of the acoustic experiment for studying the aerodynamic noise of wind turbine blade segments - 26/08/2025 01:18
- Gas flow peculiarities in a semi-closed volume during the explosion of an elongated charge of a condensed explosive substance - 26/08/2025 01:18
- Determination of the wear mechanism of the diamond tool matrix by analysis of wear particles - 26/08/2025 01:18
- Technology of co-firing coal and biomass: features, current state, and prospects - 26/08/2025 01:18
- Physico-chemical characterization of phosphatic waste: statistical approach and efficient valorization remedies (Algeria) - 26/08/2025 01:18
- Valorization of clay-based mining wastes from Oued El Aneb marble quarry for terracotta production - 26/08/2025 01:18