Analysis of the energy efficiency of a two-level voltage source inverter in the overmodulation mode
- Details
- Category: Electrical Complexes and Systems
- Last Updated on 01 September 2019
- Published on 19 August 2019
- Hits: 3440
Authors:
O.A.Plakhtii, Cand. Sc. (Tech.), orcid.org/0000-0002-1535-8991, Limited Liability Company “VО ОVЕN”, Kharkiv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
V.P.Nerubatskyi, Cand. Sc. (Tech.), orcid.org/0000-0002-4309-601X, Ukrainian State University of railway transport, Kharkiv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.; This email address is being protected from spambots. You need JavaScript enabled to view it.
D.A.Hordiienko, orcid.org/0000-0002-0347-5656, Private JSC “ELAKS”, Kharkiv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
V.R.Tsybulnyk, orcid.org/0000-0002-9895-6662, Ukrainian State University of railway transport, Kharkiv, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.; This email address is being protected from spambots. You need JavaScript enabled to view it.
Abstract:
Purpose. Increasing the output power and ensuring maximum sinusoidality of output current in a two-level voltage source inverter by implementing the overmodulation mode.
Methodology. Simulation in Matlab/Simulink environment of voltage source inverter in the overmodulation mode. Mathematical apparatus of Fourier analysis of the output current spectrum.
Findings. Modeling of the voltage source inverter in the overmodulation mode allowed obtaining a number of dependencies:
- the dependence of the VSI output power on the modulation coefficient k;
- the dependence of the total harmonic distortion of the output current and output voltage on the modulation coefficient;
- the dependence of the total harmonic distortion of the input current in VSI on the modulation coefficient.
Originality. It is established that the overmodulation mode in the voltage source inverter can significantly increase the output power and improve the sinusoidality of output voltage and output current. It is established that the dependence of the total harmonic distortion of the output current has an extremum that causes the point of maximum sinusoidality.
Practical value. The use of the overmodulation mode in a two-level voltage source inverter will ensure maximum sinusoidality of output current and minimize additional power losses in the load from higher harmonics. In addition, the overmodulation mode will significantly reduce the level of emission of higher harmonics of current into the supply network. Practical application of overmodulation mode is performed in frequency converters of the company “VО OVEN”.
References.
1. Petrenko, A.N., Tanyansky, V.I., & Petrenko, N.Ya. (2012). Additional power losses of a frequency-controlled asynchronous motor from higher voltage harmonics. Electrical Engineering and Electromechanics, (5), 34-35.
2. Kazakov, Yu.B., & Shvetsov, N.K. (2015). Calculated analysis of losses in steel of asynchronous motors when powered by frequency converters with non-sinusoidal output voltage. Messenger IHEU, 5, 1-5.
3. Plakhtii, O., Nerubatskyi, V., Ryshchenko, I., Zinchenko, O.,Tykhonravov, S.,& Hordiienko, D. (2019). Determining additional power losses in the electricity supply systems due to current’s higher harmonics. Eastern-European Journal of Enterprise Technologies, 1(8(97)), 6-13. DOI: 10.15587/1729-4061.2019.155672.
4. Arcega, F.J., & Pardina, A. (2014). Study of harmonics thermal effect in conductors produced by skin effect, IEEE Latin America Transactions, 12(8), 1488-1495. DOI: 10.1109/TLA.2014.7014518.
5. Vasil’ev, B.Yu., & Dobush, V.S. (2014). Effective сontrol algorithms semiconductor converters in asynchronous electric drive. Electrical Technology, (4), 54-61.
6. Michalsky, V.М. (2013). Means for improving the quality of electricity at the input and output of frequency converters with pulse-width modulation: monograph. Kyiv: Institute of Electrodynamics of the National Academy of Sciences of Ukraine.
7. Nerubatskyi, V.P., Plakhtii, O.A., Kavun, V.E., Mashura, A.V., Hordiienko, D.A., & Tsybulnyk, V.R. (2018). Analysis of indices of energy efficiency of autonomous voltage inverters with various modulation types. Collection of Scientific Works of the Ukrainian State University of Railway Transport, 180, 106-120.
8. Kolosov, V., & Vasechko, E. (2017). Formation of quasi-sinusoidal voltage in bridge inverters. Vestnik NTU “HPI”, 27(1249), 318-323. DOI: 10.20998/2413-4295.2018.26.14.
9. Dias, R.A., Lira, G.R., Costa, E.G., Ferreira, R.S., & Andrade, A.F. (2018). Skin effect comparative analysis in electric cables using computational simulations: 2018. In Simposio Brasileiro de Sistemas Eletricos (SBSE) (pp. 1-6). DOI: 10.1109/SBSE.2018.8395687.
10. Plakhtii, O.A., & Nerubatskyi, V.P. (2018). Analyses of energy efficiency of interleaving in active voltage-source rectifier. In 2018 IEEE 3rd International Conference on Intelligent Energy and Power Systems (IEPS), (pp. 253-258). DOI: 10.1109/IEPS.2018.8559514.
11. Blahnik, V., & Talla, J. (2016). Single-phase synchronization for traction active rectifier. In 2016 International Conference on Applied Electronics (AE). DOI: 10.1109/ae.2016.7577233.
12. Vasil’ev, B.Yu. (2015). Providing overmodulation mode and increasing energy conversion efficiency in autonomous power inverters of electric drives. Electricity, (6), 47-55.
13. Kostic, D.J., Avramovic, Z.Z., & Ciric, N.T. (2013). A new approach to theoretical analysis of harmonic content of PWM waveforms of single- and multiple-frequency modulators. IEEE Transactions on Power Electronics, 28(10), 4557-4567. DOI: 10.1109/TPEL.2012.2232309.
14. Borrega, M., Marroyo, L., Gonzalez, R., Balda, J., & Agorreta, J.L. (2013). Modeling and control of a master-slave PV inverter with n-paralleled inverters and three-phase three-limb inductors. IEEE Transactions on Power Electronics, 28(6), 2842-2855. DOI: 10.1109/TPEL.2012.2220859.
15. Fomin, O.V., Lovska, A.O., Plakhtii, O.A., & Nerubatskyi, V.P. (2017). The influence of implementation of circular pipes in load-bearing structures of bodies of freight cars on their physico-mechanical properties. Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, 6(162), 89-96.
16. Zhemerov, G.G., Tugay, D.V., & Titarenko, I.G. (2013). Simulation of AC drives system comprising multilevel inverter. Electrical еngineeringand еlectromechanics, (2), 40-47.
17. Lazzarin, T., Bauer, G., & Barbi, I. (2013). A control strategy for parallel operation of single-phase voltage source inverters: analysis, design and experimental results. IEEE Transactions on Industrial Electronics, 60(6), 2194-2204. DOI: 10.1109/TIE.2012.2193856.
18. Wei, L., Jankovic, Z., Patel, Y. P., & Hu, J. (2016). Single phase precharge control method for active front end rectifier. In 2016 IEEE Energy Conversion Congress and Exposition (ECCE). DOI: 10.1109/ecce.2016.7855436.